- RTVAL-01 status set to FAIL: Win32 app wizard fields stayed empty, OK greyed out - Verbatim technician symptom quoted verbatim in report - Interpretation: Detection.xml / package metadata malformed or missing in .intunewin archive - RTVAL-02, RTVAL-03, RTVAL-04 marked BLOCKED (all depend on RTVAL-01 PASS) - ISSUE-01 raised in Issues Found with root cause hypothesis and resolution path - Plan 10-02 stopped; gap-closure cycle required before retesting
3.9 KiB
Runtime Validation Report — ImpTune v1.1
Status: BLOCKED — RTVAL-01 FAIL; plan 10-02 stopped at task 1; gap-closure required before resuming Started: 2026-04-13 Signed off by: Signed off date:
Tenant & Environment
| Field | Value |
|---|---|
| Intune tenant (domain) | arescom.fr |
| Test device hostname | ARES-5CG5220YTM |
| Windows OS build | 26200.7171 |
| Device is Intune-managed | yes |
| Driver vendor(s) tested | ricoh.zip |
- PCL6 Driver for Universal Print |
| ImpTune commit SHA |
1c3f458583| | Package file name | Copieur_2eme.intunewin | | Package SHA256 | 0aac31ff190d21cbb4c76a81d4ad32657a5a3298e7e3fcc79a080e87cf40c333 | | Generated at | 2026-04-13 |
RTVAL-01 — Tenant ingestion
Status: FAIL
Tested: 2026-04-13
Evidence: No screenshot captured — the Intune upload form never reached a populated state. UI remained empty; there was no visible error banner to screenshot.
Verbatim symptom (technician): "The intunewin package cant be uploaded, the OK button is greyed out and none of the fields (name, platform, size, mam enabled) gets populated."
Interpretation: Intune accepted the file transfer but was unable to parse its embedded Detection.xml / package metadata. The Win32 app creation wizard stalls in this state when the .intunewin content manifest is malformed or when the embedded detection.xml is missing or structurally invalid. This is a structural defect in the package that ImpTune is generating — exactly the runtime gap RTVAL-01 is designed to catch. No portal error banner was shown because the failure occurs silently during client-side metadata extraction.
Package tested: Copieur_2eme.intunewin (SHA256 0aac31ff190d21cbb4c76a81d4ad32657a5a3298e7e3fcc79a080e87cf40c333, ImpTune commit 1c3f458)
RTVAL-02 — Install under SYSTEM (pnputil + $PSScriptRoot)
Status: BLOCKED — depends on RTVAL-01 PASS; RTVAL-01 returned FAIL (Intune cannot parse generated .intunewin). Cannot proceed until package structure defect is resolved. Evidence: (none — test not reached) Notes:
RTVAL-03 — Detection rule reports Installed
Status: BLOCKED — depends on RTVAL-01 PASS; RTVAL-01 returned FAIL (Intune cannot parse generated .intunewin). Cannot proceed until package structure defect is resolved. Evidence: (none — test not reached) Notes:
RTVAL-04 — Uninstall under SYSTEM
Status: BLOCKED — depends on RTVAL-01 PASS; RTVAL-01 returned FAIL (Intune cannot parse generated .intunewin). Cannot proceed until package structure defect is resolved. Evidence: (none — test not reached) Notes:
Issues Found
ISSUE-01: .intunewin package metadata unreadable by Intune Win32 app wizard
- Discovered: 2026-04-13 during RTVAL-01
- Severity: Blocker — prevents all downstream RTVAL checks (02, 03, 04)
- Symptom: Win32 app creation wizard fields (name, platform, size, MAM enabled) remain empty after file upload; OK button stays greyed out; no portal error shown
- Root cause hypothesis: Detection.xml embedded inside the .intunewin archive is missing, malformed, or uses an unexpected schema version. The IntuneWin32App packager requires a valid
detection.xmlat the root of the archive alongside the content folder. - Affected file: Copieur_2eme.intunewin (evidence/Copieur_2eme.intunewin)
- Affected code: ImpTune .intunewin generator (commit
1c3f458) - Resolution path: Debug the generator to verify Detection.xml is being created, embedded, and follows the expected Intune Win32 app manifest schema. Recommended: run
/gsd:debugon the .intunewin generator, OR let phase verification surface this as a gap and use/gsd:plan-phase 10 --gapsto draft a gap-closure plan. - Status: Open — plan 10-02 stopped; gap-closure cycle required before retesting
Sign-off
- All five RTVAL criteria PASS or have documented rationale
- Evidence files committed under
evidence/ - Signed by: ___________________